Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Disconnect black wires from the thermistor
Disconnect black wires from the thermistor
Measurement:
Measure the resistance across the exposed terminals of the thermistor. Resistance will vary according to the temperature of the water. The lower the temperature the higher the resistance.
The resistance should conform to the table below:
Reconnect leads after test.
The resistance should conform to the table below:
| Temperature °C | Resistance in kOhms |
| 30-50 | 9.8-4.7 |
| 50-70 | 4.7-2.4 |
| 70-90 | 2.4-1.3 |
| 90-110 | 1.3-0.1 |

Isolate as per TOPs P4
and refit as necessary