Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove the black leads from the flow thermistor
Remove the black leads from the flow thermistor
Measurement:
Measure the resistance across the exposed terminals of the thermistor. Resistance
will vary according to the temperature of the water. The lower the temperature
the higher the resistance.
The resistance should conform to the table below:
Reconnect leads after test.
will vary according to the temperature of the water. The lower the temperature
the higher the resistance.
The resistance should conform to the table below:
| Temperature °C | Resistance in kOhms |
| 30-50 | 9.8-4.7 |
| 50-70 | 4.7-2.4 |
| 70-90 | 2.4-1.3 |
| 90-110 | 1.3-0.1 |

Isolate as per TOPs P4
and refit as necessary