Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Gas meter test dial will have to be viewed during ignition sequence
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance by depressing reset switch.
Observe gas meter test dial, does it show that gas is flowing during the ignition sequence?
Note:
There will be approximately 15 seconds until the first attempt at ignition, then there will be a second attempt after 25 seconds then a third after 50 seconds. Then appliance should then go to lock out.
No other appliances must be in use during test.
Observe gas meter test dial, does it show that gas is flowing during the ignition sequence?
Note:
There will be approximately 15 seconds until the first attempt at ignition, then there will be a second attempt after 25 seconds then a third after 50 seconds. Then appliance should then go to lock out.
No other appliances must be in use during test.