Set Appliance State:

Mains Power Off
Set Multimeter to AC Volts Set meter to measure AC Volts
Attach multimeter probes to the inline connectors on the gas valve leads (+ve brown lead -ve to yellow lead)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset lockout if necessary.
Allow fan to run and ignition sequence to commence.
After approximately 15 seconds is voltage present at the connections?
Expected voltage approximately 26 Volts AC
Note: Voltage will only be present for 2 to 3 seconds if burner does not ignite.