Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Gain access to PCB (use Insulation Mat as required)
Remove connector X5 from the PCB

Measurement:

Measure the resistance across connection 3 (purple) and 4 (purple) at connector X5. The resistance will depend upon the temperature of the water the hotter the water the lower the resistance.
The resistance should conform to the table below.
Temperature °CResistance in kOhms
20-2512.5-11.0
25-3011.0-10.0
30-3510.0-5.5
35-405.5-4.0

Ensure that test is carried out at disconnected connector X5
Reconnect connector after test.