Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
ON/OFF Switch ON
Summer/Winter button set to Summer
CH Temperature selector to minimum
DHW Temperature selector to maximum
Attach a U-gauge to the burner pressure test point
Summer/Winter button set to Summer
CH Temperature selector to minimum
DHW Temperature selector to maximum
Attach a U-gauge to the burner pressure test point
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Does the boiler ignite and run at correct burner pressure ?
Note:
When pressure gauge is removed the pressure test point
should be tightened and checked for gas tightness.
Note:
When pressure gauge is removed the pressure test point
should be tightened and checked for gas tightness.