Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect one of the orange wires from the sensor
Measurement:
Measure the resistance across the exposed terminals of the sensor.
The resistance depends on temperature and should conform to the table below:
Reconnect wire after test.
The resistance depends on temperature and should conform to the table below:
| Temperature °C | Resistance in kOhms |
| 20 - 30 | 10.0 - 6.0 |
| 30 - 40 | 6.0 - 4.1 |
| 40 - 50 | 4.1- 3.1 |
| 50 - 60 | 3.1 - 1.8 |
| 60 - 70 | 1.8 - 1.2 |
| 70 - 75 | 1.2 - 0.9 |
Reconnect wire after test.

Isolate as per TOPs P4
and refit as necessary