Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Turn Hot Water Tap On
Note the pressure reading on the air pressure switch
Connect the air pressure switch charge kit to +ve connection on the air pressure switch
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run.
Increase the pressure via the syringe to that indicated on the pressure switch.
Does sparking now occur?
Note:
If sparking does not occur when the specified pressure
is applied it is permissible to increase the pressure by 50%
100 Pascals = 1mbar / 50 Pascals = 0.5mbar