Set Appliance State:
Mains Power Off
Gas Off
Turn Hot Water Tap On
ON/OFF Switch ON
Summer/Winter button set to Summer
CH Temperature selector to minimum
DHW Temperature selector to maximum
Summer/Winter button set to Summer
CH Temperature selector to minimum
DHW Temperature selector to maximum
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage across the Live connection (brown wire) and Neutral connection (blue wire) at the fan.

Isolate as per TOPs P4
and refit as necessary