Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the connector from the pump assembly

Measurement:

Test 1:
Measure the resistance between the bottom and middle pins on the pump.
Expect a resistance of approximately 237 ohms.
(If pump has been replaced with an ErP version
then resistance will be significantly higher)

Test 2:
Measure between the top and bottom pins on the pump.
Expect a resistance of 1 MOhm or greater.
Are the resistances as expected?