Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Turn Hot Water Tap On
ON/OFF Switch ON
Summer/Winter button set to Winter
CH Temperature selector to maximum
DHW Temperature selector to maximum
Remove the diverter valve head
Summer/Winter button set to Winter
CH Temperature selector to maximum
DHW Temperature selector to maximum
Remove the diverter valve head
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Diverter valve motor spindle should be fully out (DHW position).
Turn DHW tap off.
Does spindle retract to the CH position?
There may be a delay before demand is recognised.
Turn DHW tap off.
Does spindle retract to the CH position?
There may be a delay before demand is recognised.
Isolate as per TOPs P4
and refit as necessary