Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Electrically disconnect flow switch at the inline connector
Measurement:
Measure the resistance across the DHW flow microswitch switch white and black wires (at the inline connector end that goes to microswitch).
Resistance should be open circuit.
Turn hot tap ON.
Measure the resistance across the DHW flow microswitch white and black wires (at the inline connector end that goes to microswitch).
Resistance should be closed circuit.
Reconnect inline connector after test.
Resistance should be open circuit.
Turn hot tap ON.
Measure the resistance across the DHW flow microswitch white and black wires (at the inline connector end that goes to microswitch).
Resistance should be closed circuit.
Reconnect inline connector after test.

Isolate as per TOPs P4
and refit as necessary