Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Turn Hot Water Tap On
ON/OFF Switch ON
Summer/Winter button set to Summer
CH Temperature selector to minimum
DHW Temperature selector to maximum
Electrically disconnect pump flow microswitch at its inline connector
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow pump to run.
Measure resistance across the black and white wire at the inline connector (end that runs to the microswitch).
Resistance should be closed circuit.
Isolate Mains Power to appliance as per TOP's P4

Repeat test.
Resistance should be open circuit.
Replace microswitch after test.