Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance if required.
(press and hold the reset button for 4 seconds then release)
Allow the fan to run and the ignition sequence to commence.
Monitor the DC voltage to the gas valve during the ignition sequence, 16V DC or greater should be present during the sparking stage of the ignition cycle.
Is the voltage measured as expected?
Note:
Appliance will attempt to ignite 5 times before lockout, reset as necessary to complete the test.