Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC volts between pin 6 on connector X2 and an earth (use the copper pipe to the gas valve as earth).
Expected voltage approximately 2.2V DC.
Is the voltage measured as expected?
Expected voltage approximately 2.2V DC.
Is the voltage measured as expected?

Isolate as per TOPs P4
and refit as necessary