Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Remove ignition electrode from the burner door
Screw the ignition electrode onto the heat exchanger mounting bracket (as shown)
Screw the ignition electrode onto the heat exchanger mounting bracket (as shown)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as required.
Allow appliance to commence its ignition sequence.
Approximately 5 seconds after the fan has started,
can sparking be observed between the electrodes?
Allow appliance to commence its ignition sequence.
Approximately 5 seconds after the fan has started,
can sparking be observed between the electrodes?
Isolate as per TOPs P4
and refit as necessary