Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Remove connector from the diverter valve and make safe
Ensure NO demands
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1:
Press the reset button on the front of the appliance, while the boiler runs its start up sequence measure the dc voltage between pin 7 (blue) on connector X2 and the earth point on the boiler chassis.
Expect the voltage to fluctuate between 0 and 22 vdc and then settle at 22 vdc after approximately 5 seconds.
Test 2:
Press the reset button on the front of the appliance, while the boiler runs its start up sequence measure the dc voltage between pin 17 (brown) on connector X2 and the earth point on the boiler chassis.
Expect the voltage to fluctuate between 0 and 22 vdc and then settle at 22 vdc after approximately 5 seconds.