Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X2 (blue) from the PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure the voltage between pin 2 at X35 on the PCB to a suitable earth point.
Voltage should be approximately 22V DC.
Test 2:
Measure the voltage between pin 4 at X35 on the PCB to a suitable earth point.
Voltage should be approximately 5V DC.
Measure the voltage between pin 2 at X35 on the PCB to a suitable earth point.
Voltage should be approximately 22V DC.
Test 2:
Measure the voltage between pin 4 at X35 on the PCB to a suitable earth point.
Voltage should be approximately 5V DC.

Isolate as per TOPs P4
and refit as necessary