Set Appliance State:
Mains Power Off
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage at pin 3 (Red) at connector X2 and a suitable earth.
Expect 4.6 Vdc or greater.
Note:
Each pin on the PCB connector is numbered.
Expect 4.6 Vdc or greater.
Note:
Each pin on the PCB connector is numbered.

Isolate as per TOPs P4
and refit as necessary