Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector X18 from the PCB

Measurement:

The resistances on connector X18 should conform approximately to the table below:
CON X18 (pump main supply)Expected Resistance
Brown to Blue156 Ohms
Blue to Earth Greater than 1 MOhm
Brown to EarthGreater than 1 MOhm