Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X20 from the PCB
Measurement:
Test 1:
Measure the resistance between pin 9 (Blue)
and pin 18 (Red) on connector X20.
Expect approximately 45 ohms.
Test 2:
Measure the resistance between pin 18 (red)
and the earth point on the boiler chassis.
Expected resistance greater than 1 MOhm.
Note:
Each pin on the PCB connector is numbered.
Measure the resistance between pin 9 (Blue)
and pin 18 (Red) on connector X20.
Expect approximately 45 ohms.
Test 2:
Measure the resistance between pin 18 (red)
and the earth point on the boiler chassis.
Expected resistance greater than 1 MOhm.
Note:
Each pin on the PCB connector is numbered.

Isolate as per TOPs P4
and refit as necessary