Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage between Pin 14 (Green) on X25 and a suitable earth.
Voltage should conform approximately to the table below:
System pressureVoltage dc
0 bar1.2
1 bar 1.7
2 bar2.2
3 bar2.8

Note:
1. Use the manual pressure gauge inside the appliance as the low pressure sensor may be faulty.
2.Each pin on the PCB connector is numbered.