Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Remove the connector inside the pump with Black and White wires leading to it by pulling it upwards and make safe
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the Voltage between the White and Black wires at connector X18.
Expect a voltage fluctuating between 0 and 2.3 Vac approximately every 7 seconds.
Note:
If the appliance locks out the voltage will stop fluctuating and will need to be reset to complete the test.