Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Remove the connector inside the pump with Black and White wires leading to it by pulling it upwards and make safe
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the Voltage between the White and Black wires at connector X18.
Expect a voltage fluctuating between 0 and 2.3 Vac approximately every 7 seconds.
Note:
If the appliance locks out the voltage will stop fluctuating and will need to be reset to complete the test.
Expect a voltage fluctuating between 0 and 2.3 Vac approximately every 7 seconds.
Note:
If the appliance locks out the voltage will stop fluctuating and will need to be reset to complete the test.

Isolate as per TOPs P4
and refit as necessary