INFORMATION ON ACTIVATING MAXIMUM AND MINIMUM OUTPUT TEST MODES
None
1. Press the top 2 buttons simultaneously and the menu will be displayed.
2. Using the +/- buttons scroll to installer level and press "select".
3." Enter code" will be displayed, use the +/- buttons to scroll to 17 and press "ok".
4. Installer level is now activated, used the +/- arrows to scroll to "Test Programs" and press "select".
5. Use the +/- arrows to scroll to "Check Programs" and press "select".
6. It is then possible to scroll to maximum and minimum output modes, press select to activate, to exit a mode press the return arrow.
To exit the test modes menu Press the return arrows / back buttons until the normal display is reached.