Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X2 from the PCB
Remove the connector from the diverter valve motor
Remove the connector from the diverter valve motor
Measurement:
Measure the resistance of each of the wires in the diverter valve harness as listed in the table below.
Expect continuity on each of the tests.
Also visually inspect the condition of the harness.
Note:
Each pin on the PCB connector is numbered.
| Pin on connector (X2) | Diverter Valve Connector | 8 (Pink) | Pink |
| 17 (Brown) | Brown |
| 7 (Blue) | Blue |
| 18 (Black) | Black |
Expect continuity on each of the tests.
Also visually inspect the condition of the harness.
Note:
Each pin on the PCB connector is numbered.

Isolate as per TOPs P4
and refit as necessary