Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
Attach pressure gauge to outlet pressure test point on gas valve
The outlet pressure test point is the right hand of the two ports
The outlet pressure test point is the right hand of the two ports
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow ignition sequence to commence.
With DHW demand does the does the pressure gauge show the following sequence :
Note:
When pressure gauge is removed pressure test point should be tightened & checked for gas soundness.
With DHW demand does the does the pressure gauge show the following sequence :
| STATE | PRESSURE | Fan off | 0 mb |
| To ignition | 3 mb | Burner establish | 0 mb |
Note:
When pressure gauge is removed pressure test point should be tightened & checked for gas soundness.
Isolate as per TOPs P4
and refit as necessary