Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Use Insulation Mat as required
NO demand
Gain access to PCB as necessary
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the dc voltage between connection 12 (green) and connection 9 (black) on connector X2.
The voltage measured should correspond approximately with the pressure shown on the manual gauge on the front of the appliance as per the table below:
System pressureVoltage dc
0 bar1.2
1 bar 1.7
2 bar2.2
3 bar2.8