Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the plug from X2 on the PCB and the plug from the Aqua flow sensor
Measurement:
Measure the resistance of each of the wires in the harness to the Aqua sensor from connector X2.
Expect continuity / zero resistance on each wire.
Also visually inspect the harness for good general condition.
Expect continuity / zero resistance on each wire.
Also visually inspect the harness for good general condition.

Isolate as per TOPs P4
and refit as necessary