Set Appliance State:
Mains Power Off
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
The condensate trap and drain is located on the right hand side and can be accessed from underneath the appliance.
Allow ignition sequence to run and appliance to fire.
Observe the siphon as the appliance operates does the siphon trap fill and when full does the condensate automatically clear?
Allow ignition sequence to run and appliance to fire.
Observe the siphon as the appliance operates does the siphon trap fill and when full does the condensate automatically clear?