Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X2 from the PCB
Measurement:
Measure the resistance between pin 4 and pin 22 on connector X2.
The resistance varies with temperature and should conform approximately with the table below:
Is the resistance measured as expected?
The resistance varies with temperature and should conform approximately with the table below:
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary