Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Remove black plastic covers from the back of the Control Box
Remove connector from X502 from control board
ON/OFF Switch in ON Position
Mode Selector Switch in Hot water position
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1:
Check for approximately -24 Volts DC at link W25 on Control board and terminal marked N on the Main Switchboard terminal strip.
Test 2:
Check for approximately -24 Volts DC at connector S (black lead) on Control board and terminal marked N on the Main Switchboard terminal strip.
Note.
Voltages measured will be negative.