Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X12 from the PCB
Measurement:
Test 1.
Measure resistance across the red & black terminals of connector X12.
Expected resistance approximately 1ohm, remember to take meter leads into account.
Test 2.
Measure resistance across the brown & blue terminals of connector X12.
Expected resistance approximately 100 ohms, remember to take meter leads into account.
Measure resistance across the red & black terminals of connector X12.
Expected resistance approximately 1ohm, remember to take meter leads into account.
Test 2.
Measure resistance across the brown & blue terminals of connector X12.
Expected resistance approximately 100 ohms, remember to take meter leads into account.

Isolate as per TOPs P4
and refit as necessary