Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Voltage Set meter to measure AC Volts
Use Insulation Mat as required
Remove plastic covers from the rear of the Control Box
ON/OFF Switch in ON Position
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure Voltage across the connection 4 (red wire) and connection 5 (black wire) at connector marked X12 on Main Switchboard.
Note:
This is transformer output. Expected Voltage is approximately 17 Volts AC.