Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect Sensor Lead
Measurement:
Measure resistance across the Sensor Terminal and a suitable earth point.
The resistance will vary according to the boiler temperature.
The hotter the boiler the lower the resistance, but it should conform to the table below.
The resistance will vary according to the boiler temperature.
The hotter the boiler the lower the resistance, but it should conform to the table below.
| Temperature °C | Resistance in kOhms |
| 30-40 | 2.1-1.3 |
| 40-50 | 1.3-0.8 |
| 50-60 | 0.8-0.6 |
| 60-70 | 0.6-0.4 |
| 70-80 | 0.4-0.3 |

Isolate as per TOPs P4
and refit as necessary