Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On Fully
Remove plastic top cover from Gas Valve.
(Held by one screw in the top R/H corner of the cover)
ON/OFF Switch in ON Position
CH Temp Selector in Minimum position
DHW Temp Selector in Maximum position
Mode Selector Switch in Heat and Hot water position
Gas On
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow Fan to run and burner to ignite.
Measure Voltage across the connections of the Modulating Solenoid.
At full rate the expected Voltage is approximately 18 Volts DC.