Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Use Insulation Mat as required
Disconnect spark generator harness from PCB
Remove plastic covers from the rear of the Control Box
Apply demand
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

If required reset boiler, turn CH / DHW control to reset position.
Measure voltage across spark generator connection as indicated on rear of PCB, and the neutral connection on the mains supply.
Allow ignition sequence to commence.
Expect approximately 50 volts AC for about 10 seconds before the appliance goes into lockout.