Set Appliance State:
Mains Power Off
CH Demand
Main On/Off Control in the On position
Heating Control to Heating & Hot Water
CH Temperature Control to Maximum
Heating Control to Heating & Hot Water
CH Temperature Control to Maximum
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
If a fault code is displayed press boiler 'Reset' button.
Measure DC Voltage between red wire of Programmer's connecting ribbon cable and earth.
Voltage measured should lie between 18V and 22V DC.
Measure DC Voltage between red wire of Programmer's connecting ribbon cable and earth.
Voltage measured should lie between 18V and 22V DC.

Isolate as per TOPs P4
and refit as necessary