Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Remove the sensor by pulling down at the front and pushing gently back

Observation:

Check the two connections between Sensor and Gas Valve.
Note.
Both connections should have a sealing 'O' ring for correct operation.