Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
ON/OFF switch in ON position
DHW temp selector to MAX
Attach temperature clamps to primary flow and return pipes as indicated
DHW temp selector to MAX
Attach temperature clamps to primary flow and return pipes as indicated
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow fan to run and the boiler to ignite.
Run the hot water for at least 2 minutes while observing the temperature differential between the flow and return.
The differential should remain below 20°C throughout the test.
Note:
If another fault with the hot water is present (e.g. CH heats on DHW operation) click HERE to investigate.
Run the hot water for at least 2 minutes while observing the temperature differential between the flow and return.
The differential should remain below 20°C throughout the test.
Note:
If another fault with the hot water is present (e.g. CH heats on DHW operation) click HERE to investigate.