Set Appliance State:
Mains Power Off
Run hot water tap until water cool then turn tap OFF
DHW temperature selector to MAX
DHW temperature selector to MAX
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow boiler to carry out ignition sequence and burner to ignite.
(if boiler returns to lockout before ignition select that option below)
While observing the burner through the sight glass turn the DHW temperature control to MINIMUM to disable preheat.
Does the burner extinguish immediately or does the burner stay alight after demand. Does the fault code reoccur?
(if boiler returns to lockout before ignition select that option below)
While observing the burner through the sight glass turn the DHW temperature control to MINIMUM to disable preheat.
Does the burner extinguish immediately or does the burner stay alight after demand. Does the fault code reoccur?