Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Apply DHW demand and measure the voltage between
pin 21 (green wire) and pin 23 (black wire) at the
large multi-pin connector (X2) on the PCB.
Expect a voltage of approximately 2.5 volts DC.
Note:
There are two types of harness available for this boiler, the alternate harness will have 3 pink wires in place of the red, black and green wires. For testing purposes the function and the location of each wire is the same.