Set Appliance State:
Mains Power Off
Isolate Mains Power to appliance as per TOPs P4
Ensure boiler is cool
Ensure boiler is cool
Measurement:
Remove the wire from the thermistor and measure the resistance across the terminal on the thermistor and the boiler chassis.
The resistance measured will depend on boiler temperature and should equal to or greater than 800ohms.
Replace lead after test.
The resistance measured will depend on boiler temperature and should equal to or greater than 800ohms.
Replace lead after test.

Isolate as per TOPs P4
and refit as necessary