Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Measurement:
Disconnect the two wires from the water section rear microswitch and measure the resistance across the microswitch terminals.
Repeat the test with the water section front microswitch.
Reconnect wires after test.
Repeat the test with the water section front microswitch.
Reconnect wires after test.

Isolate as per TOPs P4
and refit as necessary