Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Ensure the burner has been operating with a CH demand and the boiler has reached normal operating temperature and the diverter valve spindle is fully extended
Measurement:
Remove the diverter valve microswitch cover and disconnect the microswitch multiplug.
Measure the resistance across the grey wire and the blue wire on the 3 terminal diverter valve microswitch.
Measure the resistance across the grey wire and the blue wire on the 3 terminal diverter valve microswitch.

Isolate as per TOPs P4
and refit as necessary