Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
VAILLANT HOME / GLOWWORM (ENERGY / HOME / ULTIMATE 2 / ULTIMATE 3 / SUSTAIN) 35 COMBI
GLOBALLY REPLACED
CASE REMOVAL
NOTE: THE
START UP DISPLAY
ENSURE NO DEMANDS
SELF CHECK AND APPLIANCE SET UP
ENSURE NO DEMANDS
OBSERVATION FAN RUNS DHW
TURN HOT WATER TAP ON WITH A FLOW RATE OF 4 L/MIN
OBSERVATION BURNER IGNITION AND ESTABLISH
BOILER DHW THERMOSTAT SETTING TO MAX
OBSERVATION BOILER RESPONDS TO CH DEMAND
BOILER CH THERMOSTAT SETTING TO MAX
HEADER FOR FLOW THERMISTOR FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR RETURN THERMISTOR FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F70 FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F75 AND F22 FAULT CODE
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F73 AND F74
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F64, F71, F84 AND F85
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F89
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F61 AND F88
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F49
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F86
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR FAULT CODE CON OR ERR
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F67 AND F87
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F62 AND F27
INTENTIONALLY BLANK HEADER FOR FAULT CODE
HEADER FOR F29
INTENTIONALLY BLANK HEADER FOR FAULT CODE
FAULT CODE HISTORY GUIDE
RESET THE APPLIANCE
HEADER FOR FUSE INVESTIGATION
INTENTIONALLY BLANK HEADER FOR FUSE INVESTIGATION
INSPECTION FAN INTAKE - OUTSIDE MODEL SEE BUILD AND DEVELOPMENT
REMOVE THE AIR INTAKE DUCT FROM THE FAN ASSEMBLY
INFORMATION FOR OBSERVATION ADJUSTMENT DSN DISPLAY OPERATES
THE PCB'S OPERATING
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW SHOW
LITE DIAGNOSTIC
DIAGNOSIS RELIES ON
HEADER FOR QADAI FLOW THERMISTOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI RETURN THERMISTOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI DIVERTER VALVE VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI DHW FLOW TURBINE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI DIVERTER VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI AC VOLTAGE TO PUMP
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP DC VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN AC VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN AC RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
RESTRICTED OR BLOCKED FLUEWAYS
HEAT EXCHANGER
AIR INTAKE RESTRICTED OR BLOCKED
FAN C/W COMBUSTION CHAMBER COVER
MIXING WATER
PLUMBING ISSUE
PUMP SPEED CONTROL SECTION 4
HARNESS WIRING
SHORTED 2
FLOW SENSOR
FAULTY SECTION TO DHW TURBINE (SHORTED)
HARNESS WIRING
BLANK INFORMATION PAGE FOR DSN ADJUSTMENT
Z REDIRECTION
BLANK FOR QADAI
Z REDIRECTION
BLANK FOR LITE DIAGNOSTIC
Z REDIRECTION
QADAI
SENSOR
QADAI
SENSOR
QADAI
FLOW SENSOR
QADAI
3 WV ASSEMBLED
QADAI
PUMP HEAD
QADAI
FAN C/W COMBUSTION CHAMBER COVER
QADAI
GAS CONTROL VALVE
BLANK FOR TYPE OF DIAGNOSITC PROCEDURE
Z REDIRECTION
POOR
COLD WATER SUPPLY
OFF OR PARTIALLY OFF
VALVES - HYDRAULIC
RESTRICTED OR BLOCKED
FILTER
RESTRICTED OR BLOCKED
FLOW SENSOR
NO POWER TO FAN
HARNESS FAN
FAULTY 2
HARNESS - IV - ADAPTER FAN
NO DEMAND TO RUN FAN
SENSOR
NO DEMAND TO RUN FAN
SENSOR
FAULTY SECTION TO DHW TURBINE
HARNESS WIRING
FAN DOES NOT RUN
THERMISTOR FITMENT
READING STUCK
SENSOR
CASE OFF
Z REDIRECTION
FAULTY
HARNESS - IV - ADAPTER FAN
FAN CIRCUITRY RUNNING CONTINUOUSLY
FAN C/W COMBUSTION CHAMBER COVER
SELF TEST 3
PCB
FAULTY GROUND
FAN C/W COMBUSTION CHAMBER COVER
RESTRICTED OR BLOCKED
SYPHON
LOW
GAS INLET PRESSURE
RESTRICTED OR BLOCKED / POORLY SEALED
DUCT - AIR INLET
RESTRICTED OR BLOCKED / POORLY SEALED 2
DUCT - AIR INLET
RESTRICTED / BLOCKED
BURNER
WARPED OR HIGH RESISTANCE
ELECTRODE IGNITION AND SENSING
SECTION TO SPARK GENERATOR 2
HARNESS HEAT ENGINE
RESTRICTED OR BLOCKED FLUEWAYS 2
HEAT EXCHANGER
NO SPARK OR WARPED
ELECTRODE IGNITION AND SENSING
FAULTY 3
HARNESS - IV - ADAPTER FAN
SECTION TO SPARK GENERATOR
HARNESS HEAT ENGINE
RESTRICTED OR BLOCKED / [POORLY SEALED 3
DUCT - AIR INLET
RESTRICTED OR BLOCKED 2
BURNER
RESTRICTED OR BLOCKED FLUEWAYS 3
HEAT EXCHANGER
GAS VALVE DAMAGED PCB
GAS CONTROL VALVE AND PCB
LOW 2
GAS INLET PRESSURE
RESTRICTED OR BLOCKED 2
SYPHON
FAULTY 3 FAULT CODE
HARNESS - IV - ADAPTER FAN
READING STUCK
SENSOR
DIVERTER VALVE SECTION FAULTY
HARNESS WIRING
NO CHARGE
EXPANSION VESSEL
OUT OF CALIBRATION
SENSOR
OUT OF CALIBRATION
SENSOR
NOT READING FOR DHW
THERMISTOR FITMENT
INCORRECTLY SET
PARAMETER - HEATING POWER
OUT OF CALIBRATION 2
SENSOR
OUT OF CALIBRATION 2
SENSOR
WEAK OR SLOW
PUMP HEAD
DIVERTER VALVE SECTION FAULTY CH
HARNESS WIRING
CLOSED OR ONLY PARTIALLY OPEN
VALVES - HYDRAULIC AND VALVE - SERVICE
LOW 3
GAS INLET PRESSURE
POOR DHW
THERMISTOR FITMENT
OUT OF CALIBRATION 3
SENSOR
OUT OF CALIBRATION 3
SENSOR
RESTRICTED WATERWAYS
HEAT EXCHANGER
RESTRICTED OR BLOCKED
FILTER
POOR DHW 2
THERMISTOR FITMENT
OUT OF CALIBRATION 3 2
SENSOR
OUT OF CALIBRATION 3 2
SENSOR
WEAK OR SLOW 3
PUMP HEAD
RESTRICTED OR BLOCKED 2
FILTER
WEAK OR SLOW 2
PUMP HEAD
SET INCORRECTLY LOW OUTPUT
PARAMETER DSN
RESTRICTED WATERWAYS 2
HEAT EXCHANGER
LOW
SYSTEM PRESSURE
BLANK FOR FAULT CODES 2
Z REDIRECTION
NO DISPLAY
FUSE (FUSED SPUR)
NO DISPLAY
FUSE PCB
NO DISPLAY
PCB
SHORTED CAUSING BLANK DISPLAY
SENSOR - WATER PRESSURE
SHORTED
FLOW SENSOR
SPEED CONTROL SHORTED
PUMP HEAD
FAULTY
HARNESS WIRING
FAULTY 4
HARNESS - IV - ADAPTER FAN
BLANK FOR HEATING POWER DIAGNOSTIC CODES
Z REDIRECTION
FAULT CODE
SENSOR
FAULT CODE
SENSOR
INCORRECTLY SET
PARAMETER DSN
NO POWER TO PUMP
PCB
FAULTY
CABLE - POWER
LOW OR AIR PRESENT
SYSTEM PRESSURE
WEAK OR SLOW 4
PUMP HEAD
PUMP SPEED CONTROL SECTION
HARNESS WIRING
RESTRICTED OR BLOCKED 3
FILTER
FAULTY SECTION TO PRESSURE SENSOR
HARNESS WIRING
FAULT CODE THERMISTOR ISSUES
SENSOR
FAULT CODE THERMISTOR ISSUES
SENSOR
FAULT CODE F64 AND F71
THERMISTOR FITMENT
OVERHEAT
THERMISTOR FITMENT
SYSTEM PRESSURE
SYSTEM PRESSURE
WEAK OR SLOW OVERHEAT
PUMP HEAD
OVERHEAT
PCB
OVERHEAT
SENSOR
OVERHEAT
SENSOR
FAULTY OVERHEAT
CABLE - POWER
OVERHEAT
HEAT EXCHANGER
OVERHEAT
FILTER
FAULT CODE
CABLE - POWER
PUMP SPEED CONTROL SECTION 2
HARNESS WIRING
PUMP SPEED CONTROL SECTION 3
HARNESS WIRING
FAULT CODE 2
CABLE - POWER
FAULT CODE
GAS CONTROL VALVE
F49 FAULT CODE
PCB
FAULT CODE
EBUS CONTROLS
MISSING
LINK
FAULT CODE F86
UNDERFLOOR HEATING CONTROLS
FAULT CODE F87
ELECTRODE IGNITION AND SENSING
ERROR CODE
HARNESS WIRING
FAULT CODE F62 AND F27
ELECTRODE IGNITION AND SENSING
PASSING WITH FAN PRESSURE
GAS CONTROL VALVE
PASSING WITH NO FAN PRESSURE
GAS CONTROL VALVE
FAULT CODE F29
DUCT - AIR INLET
FAULT CODE F29
ELECTRODE IGNITION AND SENSING
FAULT CODE F29
HARNESS HEAT ENGINE
FAULT CODE F29
FLUE
FAULT CODE F29
BURNER
FAULT CODE F29
HEAT EXCHANGER
FAULT CODE F29
SYPHON
FAULT CODE F29
GAS INLET PRESSURE
BLANK FOR UNRECORDED FAULT 2
Z REDIRECTION
BLANK FOR FAULT CODE HISTORY
Z REDIRECTION
FUSE INVESTIGATION
CABLE - POWER
FUSE INVESTIGATION
HARNESS FAN
POOR DHW S53/54
THERMISTOR FITMENT
OUT OF CALIBRATION S53/54
SENSOR
OUT OF CALIBRATION S53/54
SENSOR
WEAK OR SLOW S53/54
PUMP HEAD
RESTRICTED WATERWAYS S53/54
HEAT EXCHANGER
RESTRICTED OR BLOCKED S53/54
FILTER
LOW FAN PRESSURE AT MAX
SYPHON
LOW FAN PRESSURE
FLUE
LOW FAN PRESSURE
BURNER
LOW FAN PRESSURE
HEAT EXCHANGER
RESTRICTED OR BLOCKED POOR DHW
DUCT - AIR INLET
AIR IN BOILER
SYSTEM PRESSURE
AIR IN BOILER 2
SYSTEM PRESSURE
AIR IN BOILER 3
SYSTEM PRESSURE
CAUSING BLANK DISPLAY
3 WV ASSEMBLED
LEAKING
FLUE PIPE GASKETS
BAFFLING WRONG MIX
GAS CONTROL VALVE
POOR DHW
PCB
NOT RECOGNISING DEMAND
FLOW SENSOR
CORRECTLY ACTIVATED
FROST PROTECTION
NOT RESPONDING TO SPEED SIGNAL
PUMP HEAD
FLOW THERMISTOR SATISFACTORY
RESULT AS EXPECTED
RETURN THERMISTOR SATISFACTORY
RESULT AS EXPECTED
PCB VOLTAGE TO DIVERTER VALVE
RESULT AS EXPECTED
DHW FLOW TURBINE
RESULT AS EXPECTED
PCB GAS VALVE VOLTAGE TOP SOLENOID
RESULT AS EXPECTED
DIVERTER VALVE MOTOR
RESULT AS EXPECTED
PUMP
RESULT AS EXPECTED
PCB POWER TO PUMP AC
RESULT AS EXPECTED
PCB DC POWER TO PUMP
RESULT AS EXPECTED
QADAI PCB AC VOLTAGE TO FAN
RESULT AS EXPECTED
FAN AC RESISTANCE
RESULT AS EXPECTED
GAS VALVE TOP SOLENOID
RESULT AS EXPECTED
HARD RESET PCB
HARD RESET PCB
RESTRICTED OR BLOCKED DHW SIDE
HEAT EXCHANGER 18 PLATES
NOT RUNNING WITH DEMAND
FAN C/W COMBUSTION CHAMBER COVER
NO 240 AC TO FAN
PCB
FAULTY FAN SECTION
HARNESS HEAT ENGINE
FAULTY FAN SECTION 2
HARNESS HEAT ENGINE
SELF TEST
EBUS CONTROLS
NOT ESTABLISHING WRONG MIX
GAS CONTROL VALVE
RESTRICTED OR BLOCKED
PIPE - FLUE
RESTRICTED OR BLOCKED 2
DRAIN - CONDENSATE (SUMP)
RESTRICTED OR BLOCKED
FLUE PIPE GASKETS
NOT RECTIFYING
SPARK GENERATOR / IGNITOR
LOW FAN PRESSURE
FAN C/W COMBUSTION CHAMBER COVER
FAULTY HALL SENSOR
FAN C/W COMBUSTION CHAMBER COVER
FAULTY FAN SECTION 3
HARNESS HEAT ENGINE
NO SPARK
SPARK GENERATOR / IGNITOR
NOT IGNITING WRONG MIX
GAS CONTROL VALVE
RESTRICTED OR BLOCKED 2
PIPE - FLUE
RESTRICTED OR BLOCKED 3
DRAIN - CONDENSATE (SUMP)
RESTRICTED OR BLOCKED 2
FLUE PIPE GASKETS
LOW FAN PRESSURE NOT IGNITING
FAN C/W COMBUSTION CHAMBER COVER
NOT IGNITING NOT OPENING
GAS CONTROL VALVE
HARNESS DAMAGED GAS VALVE
HARNESS HEAT ENGINE AND PCB
FAULTY HALL SENSOR FAULT CODE
FAN C/W COMBUSTION CHAMBER COVER
FAULTY FAN SECTION 3 FAULT CODE
HARNESS HEAT ENGINE
CH DOES NOT RESPOND
EBUS CONTROLS
CH DOES NOT RESPOND 6
INTERNAL PROGRAMMER
CH DOES NOT RESPOND 8
INTERNAL PROGRAMMER
PASSING TO RADS OR NOT MOTORING
3 WV ASSEMBLED
OPEN TOO MUCH
BYPASS
NOT OPENING TO CH
3 WV ASSEMBLED
RESTRICTED OR BLOCKED PRIMARY SIDE
HEAT EXCHANGER 18 PLATES
RESTRICTED OR BLOCKED PRIMARY SIDE 2
HEAT EXCHANGER 18 PLATES
POOR DHW 2
PCB
NOT REGISTERING PRESSURE
SENSOR - WATER PRESSURE
RESTRICTED OR BLOCKED
ELBOW
RESTRICTED OR BLOCKED
SENSOR - WATER PRESSURE
BLANK FOR SYSTEM PRESSURE FUTHER INVESTIGATION
Z REDIRECTION
BLANK FOR FAULT CODES 1
Z REDIRECTION
FUSE FURTHER INVESTIGATION
Z REDIRECTION
FUSE FURTHER INVESTIGATION 2
Z REDIRECTION
SHORTING CAUSING BLANK DISPLAY
FAN C/W COMBUSTION CHAMBER COVER
FAULTY
DISPLAY
SHORTING
HARNESS HEAT ENGINE
FLOW THERMISTOR SECTION
HARNESS HEAT ENGINE
RETURN THERMISTOR SECTION
HARNESS HEAT ENGINE
F70 FAULT CODE
PCB
NOT RUNNING
PUMP HEAD
F75 FAULT CODE
PCB
SPEED CONTROL SIGNAL
PUMP HEAD
RESTRICTED OR BLOCKED F75
SENSOR - WATER PRESSURE
NOT REGISTERING PRESSURE F75
SENSOR - WATER PRESSURE
FAULT CODE F74 AND F74
SENSOR - WATER PRESSURE
FAULT CODE THERMISTOR ISSUES
HARNESS HEAT ENGINE
FAULT CODE THERMISTOR ISSUES 2
HARNESS HEAT ENGINE
NOT RUNNING OVERHEAT
PUMP HEAD
OVERHEAT
HEAT EXCHANGER 18 PLATES
FAULT CODE F89
PCB
FAULT CODE F89 2
PUMP HEAD
FAULT CODE F89
PUMP HEAD
FAULT CODE GAS VALVE
HARNESS HEAT ENGINE
F49 FAULT CODE 2
PCB
F86 FAULT CODE
PCB
F86 FAULT CODE 2
PCB
CONNECTION FAULT CODE
DISPLAY
F87 FAULT CODE
PCB
FAULT CODE F29
PCB
FAULT CODE F29
SPARK GENERATOR / IGNITOR
FAULT CODE F29
GAS CONTROL VALVE
FAULT CODE F29
PIPE - FLUE
FAULT CODE F29
DRAIN - CONDENSATE (SUMP)
FAULT CODE F29
FLUE PIPE GASKETS
LOW FAN PRESSURE FAULT CODE F29
FAN C/W COMBUSTION CHAMBER COVER
BLANK FOR UNRECORDED FAULT
Z REDIRECTION
FUSE INVESTIGATION
PUMP HEAD
PCB BLOWING FUSE
PCB FUSE BLOWN
FUSE BLOWING
FAN C/W COMBUSTION CHAMBER COVER
BLANK FOR OVERHEAT
Z REDIRECTION
POOR DHW S53/54
PCB
RESTRICTED OR BLOCKED PRIMARY SIDE S53/54
HEAT EXCHANGER 18 PLATES
LOW GAS RATE
GAS CONTROL VALVE
LOW MAXIMUM FAN PRESSURE
FAN C/W COMBUSTION CHAMBER COVER
SHORTED CAUSING BLANK DISPLAY
HARNESS WIRING
RESTRICTED OR PERFORATED
PIPE - FLUE
RESTRICTED OR BLOCKED
DRAIN - CONDENSATE (SUMP)
DISPLAY ILLUMINATES BUT GOES OFF AFTER APPROXIMATELY 15 SECONDS
CHARACTERISTIC TEST FROM START UP DISPLAY
DHW DEMAND RECOGNISED BUT FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS DHW
DHW DEMAND NOT RECOGNISED
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS DHW
FAN RUNS CONTINUOUSLY AT HIGH SPEED
CHARACTERISTIC TEST FROM SELF CHECK AND APPLIANCE SET UP
RADIATOR SYMBOL FLASHES IN DISPLAY
CHARACTERISTIC TEST FROM SELF CHECK AND APPLIANCE SET UP
BURNER DOES NOT IGNITE AND ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
BURNER IGNITES BUT BAFFLES OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
FAULT CODE F32 SHOWN
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION AND ESTABLISH
24 VOLT EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION EXTERNAL CONTROLS FITTED
EBUS CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION EXTERNAL CONTROLS FITTED
TEMPERATURE RISE UNSATISFACTORY - RADS BEGIN TO HEAT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
TEMPERATURE RISE UNSATISFACTORY - RADS REMAIN COOL
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TEMPERATURE FLUCTUATES (RUNS HOT THEN COLD)
CHARACTERISTIC TEST FROM OPERATION DHW
BOILER REACHES TEMP RADIATORS REMAIN COOL OR DO NOT HEAT
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
BOILER AND RADIATORS FAIL TO REACH SET TEMPERATURE
CHARACTERISTIC TEST FROM OPERATION CENTRAL HEATING
ZERO OR LOW PRESSURE FLASHING
CHARACTERISTIC TEST FROM START UP DISPLAY
ELBOW RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE SENSOR AND ELBOW
PRESSURE SENSOR RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE SENSOR AND ELBOW
FAULT CODE SHOWN
CHARACTERISTIC TEST FROM START UP DISPLAY
DISPLAY DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM START UP DISPLAY
ELBOW RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE SENSOR AND ELBOW
PRESSURE SENSOR RESTRICTED OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION SYSTEM PRESSURE SENSOR AND ELBOW
PREVIOUSLY UNRECORDED FAULT SHOWN
CHARACTERISTIC TEST FROM START UP DISPLAY
BOILER CUTS OUT ON DHW AND THEN STOPS RECOGNISING DHW DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
13/01/2023 10:59:14 2212_1_50_1 28/02/2023 13:46:07
02/02/2023 14:42:45
VOLTAGE DC PUMP SPEED CONTROL SEND (DISCONNECTED)
DISCONNECT THE 3 WIRE SPEED CONTROL FROM THE PUMP ASSEMBLY AND MAKE SAFE
VOLTAGE FLOW SENSOR - SEND (FLOW SENSOR DISCONNECTED)
REMOVE THE CONNECTOR FROM THE FLOW SENSOR AND MAKE SAFE
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
VOLTAGE DIVERTER VALVE AT PCB
{GAINPCBACS}
ENSU
VOLTAGE FLOW SENSOR DHW - RETURN
{GAINPCBACS}
RESISTANCE DIVERTER VALVE MOTOR AND HARNESS
REMOVE CONNECTOR X2 FROM THE PCB
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE DC PUMP SPEED CONTROL SEND (DISCONNECTED)
DISCONNECT THE 3 WIRE SPEED CONTROL FROM THE PUMP ASSEMBLY AND MAKE SAFE
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE
RESISTANCE HARNESS FAN AC
REMOVE CONNECTOR X12 FROM THE PCB
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE HARNESS FAN IV
REMOVE THE 4 WIRE HARNESS FROM THE FAN ASSEMBLY AND THE
MAIN HARNESS AT THE INLINE CONNECTOR
RESISTANCE HARNESS FAN IV
REMOVE THE 4 WIRE HARNESS FROM THE FAN ASSEMBLY AND THE
MAIN HARNESS AT THE INLINE CONNECTOR
OBSERVATION EXTERNAL CONTROLS FITTED - SELF TEST
GAIN ACCESS TO PCB
DISCONNECT EBUS CONTROLS - SELF TEST
REMOVE EBUS WIRING CONNECTIONS AND MAKE SAFE
REMOVE WIRE LINK BETWEEN THE 24 VOLT CONNECTIONS
VOLTAGE RECTIFICATION AT PCB
{GAINPCBACS}
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
RESISTANCE HARNESS SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND MAKE SAFE
VOLTAGE FAN HALL SENSOR AT PCB
{GAINPCBACS}
RESISTANCE HARNESS FAN DC COMPLETE
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE HARNESS FAN IV
REMOVE THE 4 WIRE HARNESS FROM THE FAN ASSEMBLY AND THE
MAIN HARNESS AT THE INLINE CONNECTOR
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
RESISTANCE GAS VALVE AND HARNESS
{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE
RESISTANCE HARNESS FAN DC COMPLETE
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE HARNESS FAN IV
REMOVE THE 4 WIRE HARNESS FROM THE FAN ASSEMBLY AND THE
MAIN HARNESS AT THE INLINE CONNECTOR
OBSERVATION EXTERNAL CONTROLS FITTED
GAIN ACCESS TO THE PCB
VOLTAGE DIVERTER VALVE AT PCB
{GAINPCBACS}
ENSU
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY THE RED ARROWS
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY THE RED ARROWS
INSPECTION SYSTEM PRESSURE SENSOR AND ELBOW
PRIMARY WATER DRAINED AND DISCHARGED
REMOVE LOW WATER PRESSURE SWITCH FROM FLOW PIPE
RESISTANCE FUSE (FUSED SPUR)
REMOVE FUSE FROM FUSED SPUR
FUSE FURTHER INVESTIGATION (FUSED SPUR)
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION (PCB FUSE)
THE INFORMATION PROV
VOLTAGE DISPLAY AT MAIN PCB
{GAINPCBACS}
OBSERVATION DISCONNECT PRESSURE SENSOR
REMOVE CONNECTOR FROM PRESSURE SENSOR AND MAKE SAFE
RESISTANCE HARNESS FAN IV
REMOVE THE 4 WIRE HARNESS FROM THE FAN ASSEMBLY AND THE
MAIN HARNESS AT THE INLINE CONNECTOR
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
INSPECTION SYSTEM PRESSURE SENSOR AND ELBOW
PRIMARY WATER DRAINED AND DISCHARGED
REMOVE LOW WATER PRESSURE SWITCH FROM FLOW PIPE
RESISTANCE HARNESS PRESSURE SENSOR
REMOVE CONNECTOR X2 FROM THE PCB
REMOVE CONNECTOR FROM PRESSURE SENSOR
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY THE RED ARROWS
RESISTANCE PUMP AC
REMOVE CONNECTOR X14 FROM THE PCB
RESISTANCE PUMP HARNESS AC
REMOVE LEFT HAND CON
RESISTANCE GAS VALVE AND HARNESS
{GAINPCBACS}
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR TO THE GAS VALVE
VOLTAGE DISPLAY AT MAIN PCB
{GAINPCBACS}
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
RESISTANCE HARNESS SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
RESISTANCE PUMP HARNESS AC
REMOVE LEFT HAND CON
RESISTANCE HARNESS FAN AC
REMOVE CONNECTOR X12 FROM THE PCB
REMOVE THE 3 WIRE CONNECTOR FROM THE FAN
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY THE RED ARROWS
INSPECTION AIR INLET DUCT AND GASKET POOR DHW
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
RESISTANCE HARNESS FLOW SENSOR
REMOVE ELECTRICAL CONNECTORS X2 FROM THE PCB AND
TO THE DHW FLOW SENSOR
OBSERVATION ADJUSTMENT DSN DISPLAY OPERATES CORRECTLY
REMOVE CONNECTOR FROM RETURN THERMISTOR AND MAKE SAFE
INSPECTION FILTER
MAINS WATER ISOLATED AND DRAINED
REMOVE THE COLD WATER ISOLATION VALVE
INSPECTION FLOW SENSOR
MAINS WATER ISOLATED
VOLTAGE DC FAN DEMAND
{GAINPCBACS}
REMOVE 4 WIRE CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESISTANCE HARNESS FAN DC COMPLETE
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
VOLTAGE FLOW SENSOR DHW - RETURN
{GAINPCBACS}
RESISTANCE HARNESS FLOW SENSOR
REMOVE ELECTRICAL CONNECTORS X2 FROM THE PCB AND
TO THE DHW FLOW SENSOR
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
RESISTANCE HARNESS FAN DC COMPLETE
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
DISCONNECT EXTERNAL CONTROLS
REMOVE ALL EXTERNAL
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
PRESSURE FAN
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
PRESSURE FAN
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE IGNITION ELECTRODE LEAD FROM
TERMINAL 3 OF THE SPARK GENERATOR
PRESSURE FAN - EQUALISATION
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
OBSERVATION SPARKING
DISCONNECT THE IGNIT
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
RESISTANCE HARNESS SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR AND CONNECTOR X21 FROM THE PCB
INSPECTION AIR INLET DUCT AND GASKET
REMOVE THE AIR INLET DUCT FROM THE FAN ASSEMBLY
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
VOLTAGE FAN HALL SENSOR AT PCB
{GAINPCBACS}
BYPASS EXTERNAL CONTROLS - 240V
DISCONNECT 240V EXTE
BYPASS EXTERNAL CONTROLS - 24V
DISCONNECT 24V EXTER
DISCONNECT EBUS CONTROLS - CH DEMAND
DISCONNECT EBUS WIRING CONNECTIONS AND MAKE SAFE
DISCONNECT INTERNAL PROGRAMMER
REMOVE X31 (PROGRAMMER) CONNECTOR FROM THE PCB AND MAKE SAFE
DISCONNECT INTERNAL PROGRAMMER
REMOVE X31 (PROGRAMMER) CONNECTOR FROM THE PCB AND MAKE SAFE
VOLTAGE DIVERTER VALVE AT PCB
{GAINPCBACS}
ENSU
PRESSURE GAS VALVE INLET - DHW
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
RESISTANCE HARNESS DIVERTER VALVE
REMOVE CONNECTOR X2 FROM THE PCB AND
ELECTRICAL CONNECTOR TO THE DIVERTER VALVE
PRESSURE EXPANSION VESSEL
PRIMARY WATER DRAINED AND DISCHARGED
OBSERVATION MAXIMUM HEATING POWER
NO DEMANDS
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
OBSERVATION CLOSE INTEGRAL BYPASS
CLOSE THE INTEGRAL BYPASS BY TURNING
THE ADJUSTMENT SCREW CLOCKWISE
RESISTANCE HARNESS DIVERTER VALVE
REMOVE CONNECTOR X2 FROM THE PCB AND
ELECTRICAL CONNECTOR TO THE DIVERTER VALVE
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
TEMPERATURE DIFFERENTIAL DHW
TURN HOT WATER TAP O
INSPECTION HEATING FILTER
PRIMARY HEATING WATE
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
TEMPERATURE DIFFERENTIAL DHW
TURN HOT WATER TAP O
INSPECTION HEATING FILTER
PRIMARY HEATING WATE
SYSTEM PRESSURE FURTHER INVESTIGATION
THE SYSTEM PRESSURE
VOLTAGE MAINS POWER INPUT AT PCB
{GAINPCBACS}
RESISTANCE FUSE PCB
REMOVE FUSE FROM PCB
OBSERVATION DISCONNECT X2 AND X20
REMOVE CONNECTOR X2 FROM THE PCB
REMOVE CONNECTOR X20 FROM THE PCB
OBSERVATION REFIT X2
REFIT CONNECTOR X2 TO THE PCB
RESISTANCE HARNESS FAN DC COMPLETE
REMOVE THE 4 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X20 FROM THE PCB
OBSERVATION DISCONNECT FLOW SENSOR
REMOVE CONNECTOR FROM FLOW SENSOR AND MAKE SAFE
OBSERVATION DISCONNECT PUMP SPEED CONTROL
REMOVE SPEED CONTROL CONNECTOR FROM PUMP AND MAKE SAFE
RESISTANCE HARNESS DISPLAY PCB
REMOVE CONNECTOR X51 FROM THE PCB
REMOVE CONNECTOR X51 FROM THE DISPLAY PCB
RESISTANCE PUMP HARNESS AC
REMOVE LEFT HAND CON
VOLTAGE DC PRESSURE SENSOR UPLIFT
{GAINPCBACS}
INSPECTION HEATING FILTER
PRIMARY HEATING WATE
VOLTAGE DC TO PRESSURE SENSOR
REMOVE CONNECTOR FRO
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X20 FROM THE PCB
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
TEMPERATURE DIFFERENTIAL DHW
TURN HOT WATER TAP O
OBSERVATION RUN BOILER TO TEMPERATURE
BOILER CH THERMOSTAT
RESISTANCE PUMP HARNESS AC
REMOVE LEFT HAND CON
INSPECTION HEATING FILTER
PRIMARY HEATING WATE
RESISTANCE PUMP HARNESS AC
REMOVE LEFT HAND CON
OBSERVATION DISCONNECT EBUS CONTROLS
REMOVE THE EBUS WIRING AND MAKE SAFE
OBSERVATION LINK UNDERFLOOR HEATING CONTROL
REMOVE WIRES FROM TO
RESISTANCE HARNESS DISPLAY PCB
REMOVE CONNECTOR X51 FROM THE PCB
REMOVE CONNECTOR X51 FROM THE DISPLAY PCB
PRESSURE STANDING RETURN
ATTACH U GAUGE TO IN
PRESSURE GAS VALVE INLET
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT
VOLTAGE RECTIFICATION AT PCB FAULT CODE
{GAINPCBACS}
INSPECTION ELECTRODE IGNITION
REMOVE AIR INTAKE TUBE
REMOVE IGNITION ELECTRODE
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE IGNITION ELECTRODE LEAD FROM
TERMINAL 3 OF THE SPARK GENERATOR
PRESSURE FAN
NO DEMANDS
ATTACH TUBE FROM + VE CONNECTION ON FGA TO THE UPPER GAS VALVE TEST POINT
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
ACCESS PREVIOUSLY UNRECORDED
IF A NEW FAULT OCCUR
RESISTANCE THERMISTOR FLOW
REMOVE CONNECTOR FROM FLOW THERMISTOR
RESISTANCE THERMISTOR RETURN
REMOVE CONNECTOR FROM THERMISTOR
TEMPERATURE DIFFERENTIAL DHW
TURN HOT WATER TAP O
INSPECTION HEATING FILTER
PRIMARY HEATING WATE
PRESSURE FAN MAXIMUM
REMOVE THE 4 WIRE CO
INSPECTION BURNER ASSEMBLY
REMOVE COMBINED FAN,
OBSERVATION DISCONNECT DIVERTER VALVE
REMOVE THE CONNECTOR FROM THE DIVERTER VALVE AND MAKE SAFE
INSPECTION FLUE PIPE AND SUMP / GASKETS
REMOVE THE FLUE PIPE FROM FRONT OF THE APPLIANCE
System Information
- Total Tests: 624
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control