Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
NO demands
Attach tube from + ve connection on FGA to the upper gas valve test point
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset appliance as necessary.
(press and hold the power button for 4 seconds then release)
Allow the fan purge to complete.
Turn hot water tap on and allow the fan to run, monitor the pressure registered while the fan runs and the boiler attempts to ignite.
The fan pressure measured should be approximately -2mb or greater.
(e.g. -2.5mb registered on display)
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.