Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the flow sensor and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC volts between pin 3 on connector X2 and an earth connection (use the copper pipe to the gas valve as earth).
Expected voltage approximately 4.8 Vdc.
Is the voltage measured as expected?
Note.
Ensure a good connection is made or misdiagnosis may occur.
Expected voltage approximately 4.8 Vdc.
Is the voltage measured as expected?
Note.
Ensure a good connection is made or misdiagnosis may occur.

Isolate as per TOPs P4
and refit as necessary