Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Measurement:
Measure the resistance of each of the wires in the pump
speed control harness as described below.
Pin 10 on X2 to pin 2 on pump connector.
Pin 20 on X2 to pin 3 on pump connector.
Pin 19 on X2 to pin 1 on pump connector.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.
Are the resistances as expected and is the harness in good condition?
speed control harness as described below.
Pin 10 on X2 to pin 2 on pump connector.
Pin 20 on X2 to pin 3 on pump connector.
Pin 19 on X2 to pin 1 on pump connector.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.
Are the resistances as expected and is the harness in good condition?
