Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove left hand connector from pump assembly
Remove connector X14 from the PCB
Remove the end cover from the pump connector
assembly carefully as shown below
Remove connector X14 from the PCB
Remove the end cover from the pump connector
assembly carefully as shown below
Measurement:
Measure the resistance of each of the wires in the pump harness from connector X14 to the corresponding wire on the pump connector.
Expect continuity on each of the wires in the harness.
Also visually inspect the condition of the harness.
Are the resistances measured as expected and is the harness in good condition?
Expect continuity on each of the wires in the harness.
Also visually inspect the condition of the harness.
Are the resistances measured as expected and is the harness in good condition?

Isolate as per TOPs P4
and refit as necessary