Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
Locate primary system filling loop
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure for DC voltage across pin14 (red lead) of connector X2 and a suitable earth connection.
Increase the primary system pressure slowly until voltage measured reaches approximately 1.7 Vdc, this voltage corresponds to a system pressure of approximately 1 bar (see table below).